This product is a wet-laid waterproofing membrane made from a polymer-modified bitumen base—composed of bitumen, SBS, water-repellent agents, surfactants, and other additives—with a polyester felt reinforcement and anti-adhesive material applied to one or both sides. The addition of proprietary surfactants, water-penetrating agents, and other additives to enhance the compound’s creep properties, allowing it to penetrate the pores and capillaries of the concrete. This creates a combination of physical adsorption and chemical cross-linking, ensuring a strong bond between the membrane and the substrate and forming a fully enclosed, watertight waterproofing layer.

Based on the adhesive surface, they are classified as single-sided adhesive (S) and double-sided adhesive (D).
Thickness: 3.0 mm;
Width: 1000 mm;
Nominal area: 10 m².
Mark in the following order: product name, standard number, type, bonding surface, full thickness, and area.
Example: A 10 m² single-sided adhesive Type I asphalt-based polyester felt waterproofing membrane with a thickness of 3.0 mm, applied using the wet-lay method, is labeled as:
Wet-laid Waterproofing Membrane GB/T 35467-2017-PY S 3.0-10
A construction method involving the bonding of self-adhesive membranes with cement mortar solves the challenge of installing self-adhesive membranes on damp substrates. Apply a compatible cement mortar to the substrate, peel off the release liner from the upper surface of the membrane, lay it on top of the cement mortar, and properly treat the overlapping edges of the seams as required.
Key Construction Points:
◎The subgrade should be firm, clean, and sufficiently moist, with no standing water.
◎ When preparing the cement slurry, mix it thoroughly; when applying it, ensure it is compacted and smoothed out, with a thickness of typically 3–5 mm.
◎When laying the membrane, use a wooden trowel or rubber sheet to tap the surface of the membrane and work the mortar into it, ensuring that the membrane adheres tightly to the cement mortar.
◎ If the overlap area is contaminated, it must be cleaned thoroughly first; the overlap width of the membrane must be at least 80 mm.
Suitable for waterproofing the base slabs and side walls of underground and open-cut stations.
Suitable for waterproofing non-exposed roof projects, and particularly suitable for waterproofing projects where open flames cannot be used.
Applicable Standard: GB/T 35467-2017 "Wet-Lay Waterproofing Membranes"
| No. | Project | Indicators | ||
| 1 | Soluble matter content/(g/m²) ≥ | 2100 | ||
|
2 |
Tensile Properties | Tensile strength (N/50 mm) ≥ | 500 | |
| Elongation at maximum tensile force / % ≥ | 30 | |||
| Phenomena Observed During Tensile Testing | No separation between the rubber layer and the carcass base | |||
| 3 | Tear strength/N ≥ | 200 | ||
| 4 | Heat Resistance (70°C, 2 hours) | No run-off, dripping, or slippage ≤ 2 mm | ||
| 5 | Low-Temperature Flexibility / (-20°C) | No cracks | ||
| 6 | Water Impermeability (0.3 MPa, 120 min) | Waterproof | ||
|
7 |
Sheet-to-sheet peel strength (lap joint) (N/mm) ≥ | No processing | 1.0 | |
| Soaking Treatment | 0.8 | |||
| Heat Treatment | 0.8 | |||
| 8 | Oil permeability/number of sheets ≤ | 2 | ||
| 9 | Viscosity/min ≥ | 30 | ||
| 10 | Bond Strength with Cement Mortar/(N/mm) ≥ | No processing | 1.5 | |
| Heat Treatment | 1.0 | |||
| 11 | Adhesion strength to cement mortar after water immersion (N/mm) ≥ | 1.5 | ||
|
12 |
Heat Aging (80°C, 168 h) |
Tensile Retention Rate / % ≥ | 90 | |
| Elongation Retention Rate / % ≥ | 80 | |||
| Low-Temperature Flexibility / (-18°C) | No cracks | |||
| 13 | Rate of Dimensional Change / % | ±1.5 | ||
| 14 | Thermal Stability | No bulges or sagging; curling at the edges of the base shall not exceed 1/4 of the side length. | ||