This product is a waterproofing membrane composed of a self-adhesive polymer-modified asphalt base—formulated from synthetic rubbers such as SBS and SBR, tackifying resins, and high-quality petroleum asphalt—with a polyester felt reinforcement and anti-adhesive material applied to one or both sides.

Thickness: 4.0 mm;
Width: 1000 mm;
Other specifications shall be agreed upon by the buyer and seller.
Products are marked by product name, standard number, type, total thickness, area, and sequence.
Example: A 10 m² pre-applied waterproofing membrane made of polymer-modified asphalt with a polyester reinforcement and a thickness of 4.0 mm is labeled as:
Pre-applied Waterproofing Membrane GB/T 23457-2017-PY 4.0-10
Pre-lay Method: This is a common installation method for self-adhesive membranes in basement construction, also known as the reverse-adhesion method. The membrane is loosely laid on the substrate with the self-adhesive side facing up. The release liner on the top surface is peeled off, and concrete is then poured. The concrete bonds firmly to the self-adhesive side of the membrane, forming a sealed waterproof layer.
Inspect and clean the substrate → Seal joints → Mark positions and snap lines → Install membrane using the loose-lay method → Fully adhere at lap joints → Clean, trim, and inspect → Peel off the top release liner → Pour concrete
◎ Prepare the Substrate: The substrate should be level, firm, and free of standing water; all protrusions must be completely removed.
◎ Overlapping the long and short edges: Peel off the release film from the long and short overlapping edges of the roll material, then press them firmly into place using a hand-held roller.
◎ Sealing the Long and Short Edges: Seal the overlaps at the long and short edges of the roll material using 120 mm wide double-sided self-adhesive sealing tape.
Suitable for waterproofing applications in industrial and residential buildings, including roofs, basements, interiors, tunnels, subways, and municipal projects.
Suitable for waterproofing roofs with special structures, such as wooden roofs.
It is particularly suitable for waterproofing projects at oil depots, chemical plants, textile mills, and other facilities where open-flame work is not permitted.
Applicable Standard: GB/T 23457-2017 "Pre-applied Waterproofing Membranes"
| No. | Project | Indicators | |
| 1 | Soluble Matter Content/(g/m²) ≥ | 2900 | |
| 2 | Tensile Properties | Tensile strength/(N/50 mm) ≥ | 800 |
| Elongation at maximum tensile force / % ≥ | 40 | ||
| 3 | Tear Strength of Nail Rod / N | 200 | |
| 4 | Impact Resistance (0.5 kg·m) | No leaks | |
| 5 | Resistance to static loads | 20 kg, no leaks | |
| 6 | Heat Resistance | 70°C, 2 hours: no displacement, flow, or dripping | |
| 7 | Low-Temperature Flexibility | -20°C, no cracks | |
| 8 | Oil Permeability/Number of Sheets ≤ | 2 | |
| 9 | Resistance to water backflow (hydraulic gradient) | 0.8 MPa/35 mm, no water leakage for 4 hours | |
|
10 |
Bond strength with the subsequently poured concrete/(N/mm) ≥ |
No processing | 1.5 |
| Water-exposed surface | 1.0 | ||
| Sediment Pollution on the Surface | 1.0 | ||
| Ultraviolet Treatment | 1.0 | ||
| Heat Treatment | 1.0 | ||
| 11 | Bond strength with post-poured concrete after water immersion (N/mm) ≥ | 1.0 | |
|
12 |
Heat Aging (80°C, 168 h) |
Tensile Retention Rate / % ≥ | 90 |
| Elongation Retention Rate / % ≥ | 80 | ||
| Low-Temperature Flexibility | -18°C, no cracks | ||
| 13 | Rate of Dimensional Change / % | ±0.7 | |