This product is a waterproofing material manufactured by using a polymer membrane as a reinforcing substrate, coating it with a reactive self-adhesive adhesive, and then covering it with a release liner. While maintaining the polymer membrane’s excellent resistance to aging and good self-adhesive sealing properties, the adhesive contains unique active agents and water-absorbing agents to the adhesive to enhance its creep properties. Through wet installation, it undergoes a “physical adsorption and chemical cross-linking” reaction with the concrete, ensuring a strong bond between the membrane and the substrate and forming a fully enclosed, watertight waterproofing layer.

Polymer membrane-based waterproofing membranes are classified into: high-strength type (Class H) and high-elongation type (Class E). The polymer membrane may be located on the surface or in the middle of the membrane. Based on the adhesive surface, they are classified as single-sided adhesive (S), double-sided adhesive (D).
Specifications and Dimensions
Class H and Class E thicknesses: 1.5 mm, 2.0 mm; width: 1,000 mm; nominal area: 15 m², 20 m². (Other specifications may be agreed upon by the supplier and the buyer.)
Class H – High-strength; Class E – High-elongation; S – Single-sided adhesion; D – Double-sided adhesion. Mark in the following order: name, standard number, type, bonding surface, total thickness, and area. Example: A 20 m², 1.5 mm, high-strength, single-sided, wet-laid polymeric waterproofing membrane is marked as: Wet-laid Waterproofing Membrane GB/T 35467-2017-H-S-1.5-20

The substrate must be level and firm; remove any protrusions from the substrate. If the substrate is dry, thoroughly wet it until it is saturated; construction may begin once there is no standing water.
Mix thoroughly in the mixing bucket using an electric mixer, maintaining a cement-to-water ratio of 1:0.3–0.5 by weight. When preparing the mixture, first pour the water into the bucket, then add the cement. Let it soak for 10–15 minutes, then pour off the water that has risen to the surface before beginning to mix. The resulting cement slurry must be uniform, with no sediment or lumps.
Roll the sheet from both ends toward the center. When you reach the halfway point of the roll, use a utility knife to gently score the release liner from the center, taking care not to cut through the sheet. After positioning half of the roll, grasp the end of the peeled-back release film and pull it back evenly with consistent force, unrolling and applying the material as you go. As you apply it, be sure to roll it down firmly and remove any air pockets. The roll must be laid tightly and adhere securely to the substrate. Use a roller to press down firmly on the overlaps.
Suitable for waterproofing, moisture-proofing, and seepage-proofing projects on basement floor slabs, side walls, ceiling slabs, and non-exposed roofs of buildings. Particularly suitable for projects where open flames are prohibited.
Applicable standard: GB/T 35467-2017 "Wet-laid Waterproofing Membranes."
| No. | Project | Indicators | |||
| H | E | ||||
|
1 |
Tensile Properties |
Tensile strength/(N/50 mm) ≥ | 300 | 200 | |
| Elongation at maximum tensile force / % ≥ | 50 | 180 | |||
| Phenomena Observed During Tensile Testing | No separation between the adhesive layer and the polymer film substrate | ||||
| 2 | Tear strength/N ≥ | 20 | 25 | ||
| 3 | Heat Resistance (70°C, 2 hours) | No running or dripping; slippage ≤ 2 mm | |||
| 4 | Low-Temperature Flexibility (-20°C) | No cracks | |||
| 5 | Water Impermeability (0.3 MPa, 120 min) | Waterproof | |||
|
6 |
Sheet-to-sheet peel strength (lap joint) / (N/mm) ≥ | No processing | 1.0 | ||
| Soaking Treatment | 0.8 | ||||
| Heat Treatment | 0.8 | ||||
| 7 | Oil permeability/number of sheets ≤ | 2 | |||
| 8 | Viscosity/min ≥ | 30 | |||
|
9 |
Bond Strength with Cement Mortar/(N/mm) ≥ | No processing | 1.5 | ||
| Heat Treatment | 1.0 | ||||
| 10 | Adhesion strength to cement mortar after water immersion (N/mm) ≥ | 1.5 | |||