This product is formulated using a self-crosslinking acrylic emulsion as the base material, combined with specific amounts of modifiers, surfactants, additives, and pigments. The resulting coating film is tough and elastic, with strong adhesion; it forms a complete waterproofing system that combines rigidity and flexibility with the substrate, accommodates structural movement, and provides long-term waterproofing and impermeability.
They are classified into Type I and Type II based on their physical properties.
Label in the order of product name, model number, and standard number.
Example: Type I water-based polyurethane waterproof coating is labeled as:
Water-Based Polyurethane Waterproof Coating I JC/T 864-2008
Substrate Preparation: The substrate must be secure, level, and solid, free of sharp edges, loose dust, oil stains, and visible water marks. Inside and outside corners should be rounded using cement mortar or sealant. Cracks in the substrate and grooves around pipe roots should be filled with sealant.
Waterproof Coating: For a film thickness of 1.5–2.0 mm, apply the coating in 3–4 coats. Apply the next coat only after the previous one has dried (typically after 6–12 hours), and ensure that the application direction of each coat is perpendicular to that of the previous one.
◎ Do not perform construction work at temperatures below 0°C or in the rain; it is not recommended to perform construction work in extremely humid or poorly ventilated environments.
◎ After the coating has dried, take care to avoid exposure to direct sunlight and washing away by rain.
For a 1.0 mm-thick coating film, the total paint consumption is approximately 1.8–2.0 kg/m².
Suitable for waterproofing and seepage prevention projects on roofs, basements, restrooms and bathrooms, bridges, and culverts of various types of buildings;
It is particularly suitable for waterproofing projects on flat roofs and buildings with irregular shapes.
Applicable Standard: JC/T 864-2008 "Polymer Emulsion Building Waterproofing Coatings"
| No. | Item | Technical Indicators | ||
| I | II | |||
| 1 | Tensile strength, MPa ≥ | 1.0 | 1.5 | |
| 2 | Elongation at break, % ≥ | 300 | ||
| 3 | Low-Temperature Flexibility (φ10mm Rod) | -10°C, no cracks | -20°C, no cracks | |
| 4 | Impermeability (0.3 MPa, 30 min) | Waterproof | ||
| 5 | Solid Content /% ≥ | 65 | ||
| 6 | Drying Time / h | Surface drying time ≤ | 4 | |
| Time Spent on Hands-On Work ≤ | 8 | |||
|
7 |
Retained Tensile Strength After Treatment /% |
Heat Treatment ≥ | 80 | |
| Alkali treatment ≥ | 60 | |||
| Acid treatment ≥ | 40 | |||
| Artificial Climate Aging Treatment | – | 80 to 150 | ||
|
8 |
Elongation at Break After Treatment /% |
Heat Treatment ≥ |
200 |
|
| Alkali treatment ≥ | ||||
| Acid treatment ≥ | ||||
| Artificial Climate Aging Treatment ≥ | — | 200 | ||
| 9 | Heat Expansion Coefficient /% | Elongation ≤ | 1.0 | |
| Shorter than or equal to ≤ | 1.0 | |||